B. Braun Vista Basic Large Volume Infusion Pump
Questions? Speak with a Product Specialist!
Featuring robust components, the B. Braun Vista Basic Large Volume Infusion Pump is exceptionally durable and provides high reliability throughout the infusion process. Various modes and features include: pump and set-based free flow protection, straight-line tubing, quick start-up for continuous infusions by entering rate and volume, program mode and ramp/taper mode, and helpful prompts to walk the user through the programming process.
Infusion Pump Brand | B. Braun |
---|---|
Infusion Pump Type | Infusion Pump |
Features
- Robust mechanical components ensure exceptional durability.
- Two-year preventive maintenance schedule helps save money versus typical annual inspection requirements.
- Battery lasts approximately 3 years before a replacement is required.
- Sets not made with DEHP to protect patients. Needle-free sets protect both the patient and the clinician.
- Helpful prompts walk the user through the programming process.
- Easy to use, teach, and learn making it ideal for homecare settings.
Specifications
- Mechanism: Linear peristaltic volumetric infusion pump.
- Dimensions: 5.5 in (14 cm) x 9.4 in (24 cm) x 7.8 in (20 cm).
- Weight: 6.8 lb (3.1 kg).
- Power Requirements: 100 – 120 VAC, 50 – 60 Hz, 12 Watts.
- Leakage Current: Max 30 µA.
- Battery: 7.2 V, 1.2 Ah NiCd (rechargeable).
- Battery Operating Time: ~ 3.5 hours at 12 mL/hr.
- Rate Range: 0.1 to 800.0 mL/hr in 0.1 mL increments with Vista tubing.
- Volume to be Infused Range: 0.1 to 9999.9 mL.
- Occlusion Pressure: Variable Settings –
- Low: 8 PSI.
- High: 17 PSI.
- KVO Rate: 1 mL/hr or selected rate, whichever is lower.
- Flow Rate Accuracy: +/- 5% measurement time 8 hr, temp. 71.6° F.
- Alarms: Air-in-Line, low battery, plug-in-now, bag empty, downstream occlusion, door open, pump stopped, KVO, unit malfunction.
- Air-in-Line Alarm: Air bubble size 0.3 mL* or 1.5 mL/hr.**
- Memory: User option to retain last continuous and piggyback mode data upon power up. Permanent data retention in program and ramp/taper modes after pump is turned off.
- Tubing: B. Braun Vista administration sets.
- Modes/Features: Continuous and piggyback modes, program mode for variable infusions, ramp/taper mode fo TPN infusions and delay a mode for postponing infusion start and finish.
- Operating Temperatures:
- Operating: 64.4° to 95° F, 10.15 PSI to 15.37 PSI.
- Non-Operating: -14° F to 131° F, 10.15 PSI to 15.37 PSI.
- Latex Information: Components DO NOT contain natural rubber.
- Total Shelf Life: 35 months.
- Ordering Unit: ST.
- Sterile: No.